What you'll need
- Wet/dry vacuum
- Distilled white vinegar
- Funnel
- Rag and towels
- Flashlight
Step by step
- 01
Shut the system off
Turn the AC off at the thermostat and the power switch near the air handler.
- 02
Find the drain line
Locate the PVC line leaving the air handler and its capped access tee, then follow it to where it ends outside.
- 03
Vacuum the clog out
Seal the wet/dry vac hose around the outside end with a rag and run it for 1–2 minutes to pull out the sludge.
- 04
Flush with vinegar
Pour 1 cup of vinegar into the access tee to kill algae, wait 30 minutes and flush with water.
- 05
Reset and confirm
Empty the pan, reset the float switch if it tripped, restore power and check that water drips outside within 20 minutes.
Safety first
- Turn the power off before you work around the air handler.
- Never bypass a float switch. It prevents water damage.
Keep going with HVAC Maintenance & Diagnostics.
Unlock the full course, worksheets, a skill quiz and a shareable certificate. From $19/mo, cancel anytime.
Common questions
Why did my AC stop working with no error?
A full drain pan trips the float switch, which cuts power to the AC. Clearing the drain and resetting the switch restores cooling.
How often should I flush the AC drain line?
Every 1–3 months during cooling season with a cup of vinegar.